APC LX Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzteile APC LX herunter. Symmetra® LX Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
For more information call:
Tel: 800 800 4APC - US & Canada
Tel: 401 789 0204 - World wide
APC Corporate
APC North America
132 Fairgrounds Road
West Kingston, RI
02892 USA
Call: 800 800 4APC
Fax: 401 789 3710
APC Latin America
5301 Blue Lagoon Drive
Suite #610
Miami, FL 33126 USA
Call: 305 266 5005
Fax: 305 266 9695
APC Europe
APC Ireland
Ballybrit Business Park
Galway, Ireland
Call: +353 91 702000
Fax: +353 91 756909
APC Asia Pacific
APC Australia
Level 13 The Denison
65 Berry Street
North Sydney, NSW 2060
Call: +61 2 9955 9366
Fax: +61 2 9955 2844
Visit: www.apc.com
Web Support: : support. apc.com
PowerFax
: 800-347-FAXX
©2004. All rights reserved. All APC trademarks are property of American Power Conversion. Other trademarks are property of their respective owners. Specifications are subject to change without notice. PART# 996-2852A
1
7.5 hours for E×tended Run Tower Unit
2
(9) SYBT5 for E×tended Run Tower Unit
3
1397 for E×tended Run Tower Unit
4
1467 for E×tended Run Tower Unit
5
59.7 × 19 × 28.6 in for E×tended Run Tower Unit
6
151.64 × 48.26 × 72.64cm
for E×tended Run Tower Unit
7
74 ×23.6 ×39.25 in
8
187.96 ×59.94 ×99.7cm
9
32U for E×tended Run Tower Unit
Technical Specifi cations
8/12/16KVA
208V TOWER
4/8KVA
208V TOWER
8/12/16KVA
208V RM
4/8KVA
208V RM
8/12/16KVA
230V TOWER
4/8 KVA
230V TOWER
8/12/16KVA
230V RM
4/8KVA
230V RM
OUTPUT
Capacity
3.2kW/4kVA per module 2.8kW/4kVA per Module
Output Voltages
120/208 230
Available Output voltage
120/240 220,240
Effi ciency at Full Load
90%
Bypass
Internal Bypass (Automatic and Manual)
Full Load Output Voltage Distortion
Less than 5% at full Load
Output Frequency Sync to Mains
47–63 Hz
Output Freq Not Sync
60Hz +/- 0.1% for 60Hz nominal 50Hz +/- 0.1% for 50Hz nominal
Load Crest factor
up to 5 :1
INPUT
Output Connections
Hardwire 4 Wire (2PH + N + G)
(4) L14-30R &
(8) L5-20R & hardwire
4 wire (2ph +n + g)
(2) L14-30R &
(4) L5-20R & hardwire
4 wire (2ph + n +g)
Hardwire (3-wire, 1PH+N+G) (8) IEC 320 C13 & (10) IEC320 C19
Input Voltage
208,240 230 or 400 (3PH)
Input Connection
Hardwire 4 Wire (2PH + N + G) Hardwire (3-wire, 1PH+N+G) or (5-wire, 3PH + N+G)
Input Frequency
45 – 65 Hz
Input Voltage Range at Full Load
with Batteries Charging
166–276 155–276/290-480
Input Power Factor
ma×. .98 @ full load ma×. .98 @ full load
BATTERY
Typ e
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical Recharge time
3 Hours
1
Estimated Runtime Half Load
17 Mins. (Extended Run Tower: 8KVA – 106, 12KVA – 67, 16KVA – 48) 20 Mins. (Extended Run Tower: 8KVA – 123, 12KVA – 77, 16KVA – 55)
Estimated Runtime Full Load
6 Mins. (Extended Run Tower: 8KVA – 49, 12KVA – 30, 16KVA – 21) 7.5 Mins. (Extended Run Tower: 8KVA – 57, 12KVA – 35, 16KVA – 25)
Extended Runtimes
All standard models accept up to seven (7) external battery enclosures [extended run tower models accept up to six (6)]. Refer to www.apc.com for specifi c runtime information.
COMMUNICATION
Control Panel
Multi-function LCD status and control console
Audible Alarms
Alarm when on battery : distinctive low battery alarm : confi gurable delays
Included Software
PowerChute Network Shutdown; Web/SMNP Management Card installed
Interface Port
DB-9 RS-232; RJ-45 10/100 Base T (Network Management Card); 2 SmartSlots
EPO
Standard
PHYSICAL
# of Power Modules
Shipped with Unit
8KVA-2; 12KVA-3
16kVA-4
4KVA-1
8KVA -2
8KVA-2; 12KVA-3
16kVA-4
4KVA-1
8KVA -2
8KVA-2; 12KVA-3
16kVA-4
4KVA-1
8KVA -2
8KVA-2; 12KVA-3
16kVA-4
4KVA-1
8KVA -2
# of Empty Power Modules Slots
8KVA-3; 12KVA-2;
16kVA-1
4KVA-2
8KVA -1
8KVA-3; 12KVA-2
16kVA-1
4KVA-2
8KVA -1
8KVA-3; 12KVA-2
16kVA-1
4KVA-2
8KVA -1
8KVA-3; 12KVA-2
16kVA-1
4KVA-2
8KVA -1
Net weight (lbs)**
677
3
444 631 392 677
3
444 631 392
Shipping Weight (lbs)**
743
4
505 265 215 743
4
505 265 215
Dimensions H × W × D
36.9 × 19 × 28.6 in
5
26 × 19 × 28.6 in 33 × 18.6 × 27.1 in 22.5 × 18.6 × 27.1in 93.73×48.26×72.64cm
6
66.04×48.26 × 72.64 cm 83.51 ×47.24×68.83 cm 57.15 ×47.24× 68.83 cm
Shipping H × W × D
46.5 × 23.6 × 39.25 in
7
36 × 23.6 × 39.25 in 41.5 × 23.6 × 39.25 in 31 × 23.6 × 39.25 in 118.11×59.94 × 99.7cm
8
91.44× 59.94 × 99.7 cm 105.41× 59.94 ×99.7 cm 78.74 × 59.94 × 99.7 cm
U height
19U
7
13 19 13 19U
9
13U 19U 13U
ENVIRONMENT
Audible
62 dB
Thermal Output
BTU/HR Normal Mode
4995 3,485 4,995 3,485 4995 2762 3707 2762
Operating Temp C and F
0 to 40°C
Operating Relative humidity
0 to 95% non-condensing
Operating Elevation
0 to 10000 feet
Storage Temp
-15 to 45°C
Storage Relative Humidity
0 to 95% non-condensing
Storage Elevation
0 to 15000 feet
CONFORMANCE
Regulatory
UL 1778; CSA107.1,FCC Class A VDE, CE, EN50091-2, C-tick, GOST
Warranty
2 years
APC’s quality
system is
certified by
ISO 9002
standards
Engineered to deliver the highest level of business continuity possible, the
Symmetra
®
LX uses a modular, redundant architecture that can scale power and
runtime as demand increases or when higher levels of availability are required.
Advancements in this next generation design greatly decrease footprint or U-space
needed in an equipment rack, increase speed and ease of deployment and reduce
repair time. With built-in network manageability and a comprehensive portfolio
available from 4-16 kVA N+1, the on-line Symmetra LX is the choice to protect high-
performance IT and telecommunications equipment in computer rooms and small
data centers.
Symmetra
®
LX
High-performance redundant
power protection with scalable
power and runtime for IT and
telecommunications equipment
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Symmetra

For more information call:Tel: 800 800 4APC - US & CanadaTel: 401 789 0204 - World wideAPC CorporateAPC North America132 Fairgrounds RoadWest King

Seite 2 - LX Features and Benefits

For more information about Symmetra®LX, including runtimes, configuration, and services, go to www.apc.comAVAILABILITYModular design Provides fast ser

Kommentare zu diesen Handbüchern

Keine Kommentare