Apc RAID Subsystem SCSI-SATA II Bedienungsanleitung Seite 55

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 131
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 54
- 55 -
4. Fill in the size and click .
5. Done. A new dedicated cache volume has been set.
Step 2: Create VG (Volume Group).
Please refer to Step 1 of Example 1 to create VG.
Step 3: Create UDV (User Data Volume).
Please refer to Step 2 of Example 1 to create UDV. To create a user data volume
with dedicated cache volume, please follow the below procedures.
Figure 3.6.7.10
1. Select / Volume config / User data volume”.
2. Click .
3. Input a UDV name, choose a VG Name, select Dedicated cache which
is created at Step 1, and input the size for the UDV; decide the stripe
height, block size, read/write mode and set priority, finally click
.
4. Done. A UDV using dedicated cache has been created.
Tips
The minimum size of global cache volume is 40MB. The
minimum size of dedicated cache volume is 20MB.
Seitenansicht 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 130 131

Kommentare zu diesen Handbüchern

Keine Kommentare