Appendix
D-18
Note:
Because one disk group can have only one logical disk executing disk scrubbing, the events do not record ID of the
logical disk to execute disk scrubbing.
Disk scrubbing of logic disks
Event ID
0x205d
Type
TASK
Severity
NOTICE
Parameters
Scrub. Progress,
DG ID, Notify
threshold
Message
Scrub progress(y%) on DGx reach to the notify percent(z%)
Description
The progress of scrubbing on dgx has reached the pre-define threshold.
Advice
None
Event ID
0x2040
Type
TASK
Severity
INFO
Parameters
DG ID, LD_ID
Message
Scrub on DGxLDy started
Description
Disk scrubbing on dgxldy was started manually.
Advice
None
Event ID
0x204b
Type
TASK
Severity
NOTICE
Parameters
DG ID, LD_ID
Message
Scrub on DGxLDy started by schedule
Description
Scheduled disk scrubbing on dgx was started.
Advice
None
Event ID
0x2057
Type
TASK
Severity
WARNING
Parameters
DG ID, LD_ID
Message
Scrub on DGxLDy failed to start by schedule
Description
Scheduled disk scrubbing on dgxldy failed to start.
Advice
Check if the logic disk is busy or non-optimal.
Event ID
0x2041
Type
TASK
Severity
INFO
Parameters
DG ID, LD_ID,
Sector Num, Row
Num, Row Num
Message
Scrub on DGvLDw stopped with x bad sectors detected, y inconsistent rows found, and z rows
recovered
Description
Disk scrubbing on dgvldw was stopped manually, and there were x bad sectors detected, y incon-
sistent rows found, and z rows recovered.
Advice
If the number of bad sectors or inconsistent rows grows exceptionally fast or beyond a reasonable
number, consider to conduct diagnostics and replace with new disks.
Seitenansicht 214