APC 5000UXI Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzteile APC 5000UXI herunter. APC 5000UXI User manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
990-1392D 12/2005
User Manual
English
APC Smart-UPS
®
RT – UXI/UXICH
3000/5000/6000 VA 220/230/240 VAC
Tower/Rack-Mount 3U
Uninterruptible Power Supply
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - RT – UXI/UXICH

990-1392D 12/2005 User Manual EnglishAPC Smart-UPS® RT – UXI/UXICH 3000/5000/6000 VA 220/230/240 VAC Tower/Rack-Mount 3U Uninterruptible Po

Seite 2

8 Feature Function Cold Start This is not a normal condition. When there is no utility power and the UPS is off, press and hold the button to pow

Seite 3 - INSTALLATION

9 USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE OPTIONAL SMART SLOT ACCESSORY CARDS OR T

Seite 4

10 NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE OPTIONAL SMART SLOT ACCESSORY CARDS OR TERMINAL MODE. FUNCTION FAC

Seite 5 - ASIC CONNECTORS

11 CONNECT THE EPO (EMERGENCY POWER OFF) OPTION The output power can be disabled in an emergency by closing a switch connected to the EPO. Adher

Seite 6 - BATTERY SOLUTION

12 TERMINAL MODE TO CONFIGURE UPS PARAMETERS 3000/5000 VA models: Terminal Mode is a menu driven interface that enables enhanced configuration of t

Seite 7 - HIRD PARTY BATTERY SOLUTION

13 MAINTENANCE AND SERVICE INFORMATION Battery Replacement See your dealer or contact APC at the Web site, www.apc.com for information on replac

Seite 8

14 TROUBLESHOOTING Use the table below to solve minor installation and operation problems. Refer to the APC Web site, www.apc.com, for assistance w

Seite 9 - OPERATION

15 PROBLEM AND POSSIBLE CAUSE SOLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass

Seite 10 - ATTERY OPERATION

16 REGULATORY AND WARRANTY INFORMATION Regulatory Agency Approvals and Radio Frequency Warnings 220, 230, 240 V MODELS This equipment has been test

Seite 11 - USER CONFIGURABLE ITEMS

17 Declaration of Conformity

Seite 13

18 APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Ref

Seite 14

1 Introduction The APC Smart-UPS® RT is a high-performance, uninterruptible power supply (UPS) that provides protection for electronic equipment

Seite 15 - Service

2 ATTACH THE BEZEL TO THE UPS 5000/6000 VA XLI MODELS ONLY: HARDWIRING INSTRUCTIONS • Wiring must be performed by a qualified electrician. •

Seite 16 - TROUBLESHOOTING

3 BASIC CONNECTORS serial com Power management software and interface kits can be used with the UPS. Use only cables approved by APC. Any othe

Seite 17

4 CONNECT THE EXTERNAL BATTERIES Battery Safety Read and adhere to the following warnings when installing or servicing the external batteries. Fai

Seite 18 - Limited Warranty

5 THIRD PARTY BATTERY SOLUTION Batteries must be Sealed Lead-Acid type. Use 50 A, 250 VDC fuses with an Interrupt rating of ≥ 20,000 A. Ensure

Seite 19 - Declaration of Conformity

6 CONNECT EQUIPMENT AND POWER TO THE UPS 1. Connect equipment to the UPS. 2. 3000 VA models: Using a power cord, plug the UPS into a two-pole, th

Seite 20

7 OPERATION Load SMART-UPS RT FRONT DISPLAY Battery Charge Indicator Description Online The Online LED illuminates when the UPS is drawing