Operation and
Maintenance
InRow
®
RC
ACRC100
ACRC103
Seitenansicht 0
1 2 3 4 5 6 ... 55 56

Inhaltsverzeichnis

Seite 1 - Maintenance

Operation andMaintenanceInRow® RCACRC100ACRC103

Seite 2 - 동봉된 CD 안에 한국어 매뉴얼이 있습니다

InRow RC Operation and Maintenance2Safety Note: All work should be performed by American Power Conversion (APC®) authorized personnel only. Caution: K

Seite 3 - Important Information

3InRow RC Operation and MaintenanceOperationDisplay InterfaceItem FunctionCritical Alarm LED When red, a critical alarm condition exists and requires

Seite 4

InRow RC Operation and Maintenance4Using the DisplayEvery time you apply power to the APC InRow RC, the display initializes and runs an LED and alarm

Seite 5 - Contents

5InRow RC Operation and MaintenanceNavigating the main menuSelector arrow. Press the up or down arrow key to move the selector arrow  to a main menu

Seite 6

InRow RC Operation and Maintenance6Using the Path statementSelect the main- and sub-menu options specified in the path statement to view or configure

Seite 7

7InRow RC Operation and MaintenanceStart the cooling unitPath: Main Menu>On/Standby>OperatePress the ENTER key to change the setting to On. The

Seite 8

InRow RC Operation and Maintenance8CommissioningWarning: Procedures in this chapter should only be performed by qualified, APC-trained personnel.Warni

Seite 9 - General Information

9InRow RC Operation and MaintenanceMechanical inspectionCaution: Failure to properly install piping may result in improper cooling unit operation.User

Seite 10

InRow RC Operation and Maintenance10Start-upCaution: Starting the equipment in a high-humidity environment may lead to excessive condensation and equi

Seite 11 - Operation

11InRow RC Operation and MaintenanceSet Up General ConfigurationThe cooling group configuration options are set during the commissioning of the coolin

Seite 12 - Using the Display

This manual is available in English on the enclosed CD.Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar.Deze handleiding staat in

Seite 13 - Navigating sub-menus

InRow RC Operation and Maintenance12Set Up ContactsInput and output contactsPath: Main > Configure Unit > Discrete I/OEach cooling unit supports

Seite 14 - NTER key to select the

13InRow RC Operation and MaintenanceSet Up Cooling Group ConfigurationThe cooling group configuration determines how the cooling group should operate.

Seite 15 - Stop the cooling unit

InRow RC Operation and Maintenance14Control the EnvironmentThe InRow RC utilizes a chilled water coil, a valve to modulate fluid flow through the chil

Seite 16 - Commissioning

15InRow RC Operation and MaintenancePID settingsPath: Main > Set Group PID The Proportional plus Integral plus Derivative (PID) loop is used to con

Seite 17 - Final inspection

InRow RC Operation and Maintenance16Tune the PID loopA qualified service technician must tune the PID loop to optimize the performance of the cooling

Seite 18 - Start-up

17InRow RC Operation and MaintenanceRun hoursThe cooling unit records the number of hours each of its components has operated. When a component is rep

Seite 19 - Set Up General Configuration

InRow RC Operation and Maintenance18Set Up the DisplaySet display settings including the time and date, temperature units, passwords, and time-out set

Seite 20 - Set Up Contacts

19InRow RC Operation and MaintenanceView Status ReadingsThe display interface provides several options for viewing the status of the cooling group, it

Seite 21 - Configure Modbus

InRow RC Operation and Maintenance20Cooling group statusPath: Main > View Group StatusThe cooling group status screens provide information about th

Seite 22 - Control the Environment

21InRow RC Operation and MaintenanceEvent LogThe event log saves status information and a message each time a change in the Group is detected. Alarms

Seite 23 - PID settings

Important InformationAPC Legal DisclaimerThe information presented in this manual is not warranted by the American Power Conversion Corporation to be

Seite 24 - Tune the PID loop

InRow RC Operation and Maintenance22Alarm messages and suggested actionsNote: Critical alarm—An alarm that requires immediate action and prevents the

Seite 25 - Service intervals

23InRow RC Operation and MaintenanceEntering Fluid Temperature Sensor FaultWarning • Make sure the sensor is connected properly.• Replace the sensor.•

Seite 26 - Set Up the Display

InRow RC Operation and Maintenance24Group Communication Lost Warning • Make sure the number of units in the group is configured properly and the A-Lin

Seite 27 - View Status Readings

25InRow RC Operation and MaintenanceReturn High Temperature ViolationWarning • Make sure the temperature sensor is connected properly. • Make sure the

Seite 28 - About the cooling unit

InRow RC Operation and Maintenance26Network Management CardSet Up Network ConfigurationConfigure the network settings for the Network Management Card

Seite 29 - Event Log

27InRow RC Operation and MaintenanceQuick ConfigurationThe InRow RC is shipped with a Network Management Card that allows for the management of the ai

Seite 30

InRow RC Operation and Maintenance28APC Device IP Configuration WizardYou can use the APC Device IP Configuration Wizard at a computer running Microso

Seite 31

29InRow RC Operation and MaintenanceDHCP. You can use a RFC2131/RFC2132-compliant DHCP server to configure the TCP/IP settings for the Network Managem

Seite 32

InRow RC Operation and Maintenance30Remote access to the control consoleFrom any computer on the same network as the Network Management Card, you can

Seite 33

31InRow RC Operation and MaintenanceControl consoleAfter you log on at the control console, as described in “Remote access to the control console” on

Seite 35 - Quick Configuration

InRow RC Operation and Maintenance32Telnet/SSHYou can access the control console through Telnet or Secure SHell (SSH), depending on which is enabled.

Seite 36

33InRow RC Operation and MaintenanceSimple Network Management Protocol (SNMP)SNMPv1 only. After you add the PowerNet® MIB to a standard SNMP MIB brow

Seite 37 - 04) is the length

InRow RC Operation and Maintenance34Recovering From a Lost PasswordUse a local computer (a computer that connects to the InRow RC through the serial p

Seite 38

35InRow RC Operation and MaintenanceMaintenanceMonthly Preventive MaintenanceThe following pages can be photocopied and used during the maintenance pr

Seite 39 - Accessing a Configured Unit

InRow RC Operation and Maintenance36Mechanical Check the fans. All components should be moving freely with no signs of binding or damages.  Verify t

Seite 40 - Telnet/SSH

37InRow RC Operation and MaintenanceSemi-Annual Preventive MaintenancePerform all the Monthly/Quarterly Preventive Maintenance items and the items bel

Seite 41

InRow RC Operation and Maintenance38TroubleshootingProblem Possible Cause Corrective ActionControls are erratic or inoperative• Inlet temperature to

Seite 42 - NTER, repeatedly if

39InRow RC Operation and MaintenanceWater carryover • Improper fan speed selected • Select the next highest fan speed setting. For example, change th

Seite 43

InRow RC Operation and Maintenance40Alarms do not show up on monitoring equipment (Form C)• External monitoring equipment is not receiving power or is

Seite 44 - Functional tests

41InRow RC Operation and MaintenanceWarrantyOne-Year Factory WarrantyThe limited warranty provided by American Power Conversion (APC®) in this Stateme

Seite 45 - Cleanliness

ContentsInRow RC Operation and MaintenanceiGeneral Information... 1Overview . . . . . . . . . .

Seite 46 - Troubleshooting

InRow RC Operation and Maintenance42IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIA

Seite 47

43InRow RC Operation and MaintenanceWarranty ProceduresClaimsTo obtain service under the warranty, contact APC Customer Support (see the back cover of

Seite 49 - Warranty

IndexInRow RC Operation and Maintenance 45AAdjust the screen 18Admin password 6Air filter interval 17Arrow keys 3BBeeperdisable key click 18Boot mode

Seite 50 - Warranty claims

46 InRow RC Operation and MaintenancePasswordadmin 6changing 18device 6invalidate 18time-out 18PID controlsD (derivative) 15gain setting 15I (integral

Seite 51 - Warranty Procedures

Radio Frequency InterferenceChanges or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s

Seite 52

10/2007990-2681B-001*990-2681B-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any o

Seite 53

InRow RC Operation and MaintenanceiiSet Up Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Input and outp

Seite 54

InRow RC Operation and MaintenanceiiiQuick Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Overview . . .

Seite 55 - Radio Frequency Interference

InRow RC Operation and MaintenanceivWarranty Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Claims . . . . . .

Seite 56 - *990-2681B-001*

1InRow RC Operation and MaintenanceGeneral InformationOverviewSave these instructionsThis manual contains important instructions that must be followed