990-2687C 05/2010
Smart-UPS
®
RT UXI/UXICH
Uninterruptible Power Supply
SURT 8000/10000 VA
220/230/240 VAC
Tower/Rack-Mount 6U
English
2010 APC by Schneider Electric. APC, the APC logo, Smart-UPS and PowerChute are owned by Schneider Electric
Industries S.A.S., American Power Conversion Corporation, or affiliated companies. All other trademarks are the property of
their respective owners.
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - RT UXI/UXICH

990-2687C 05/2010 Smart-UPS® RT UXI/UXICH Uninterruptible Power Supply SURT 8000/10000 VA 220/230/240 VAC Tower/Rack-Mount 6U English

Seite 2 - INSTALLATION

9 OPERATION Load SMART-UPS RT FRONT DISPLAY Battery Charge Indicator Description Online The Online LED illuminates when the UPS is drawing

Seite 3 - 220/230/240 V MODELS

10 Feature Function Normal/Bypass Manual bypass enables the user to manually put connected equipment into bypass mode. While in bypass mode the uti

Seite 4

11 USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, SMART SLOT ACCESSORY CARDS, OR TERMINA

Seite 5 - ASIC CONNECTORS

12 NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE, SMART SLOT ACCESSORY CARDS, OR TERMINAL MODE. FUNCTION FACTORY DEF

Seite 6 - BATTERY SOLUTION

13 CONNECT THE EPO (EMERGENCY POWER OFF) The output power can be disabled in an emergency by closing a switch connected to the EPO. Adhere to na

Seite 7 - HIRD PARTY BATTERY SOLUTION

14 MAINTENANCE, SERVICE Battery Replacement See your dealer or contact APC at the Web site, www.apc.com for information on replacement battery mod

Seite 8

15 TROUBLESHOOTING Use the table below to solve minor installation and operation problems. Refer to the APC Web site, www.apc.com, for assistanc

Seite 9

16 PROBLEM AND POSSIBLE CAUSE SOLUTION BYPASS LED ILLUMINATES The bypass switch has been turned on manually or through an accessory. If bypass is t

Seite 10 - OPERATION

17 RADIO FREQUENCY AND WARRANTY INFORMATION Radio Frequency Warnings This equipment has been tested and found to comply with the limits for a Cl

Seite 11 - ATTERY OPERATION

1 Introduction The APC® by Schneider Electric Smart-UPS® RT is a high-performance, uninterruptible power supply (UPS) that provides protection f

Seite 12 - USER CONFIGURABLE ITEMS

2 ATTACH THE BEZEL TO THE UPS HARDWIRING INSTRUCTIONS • Wiring must be performed by a qualified electrician. • Adhere to all national and local

Seite 13

3 1. Switch the UPS input circuit breaker (see A in diagram) and utility circuit breakers OFF. 2. Remove the input access panel, (see B in dia

Seite 14

4 CIRCUIT BREAKERS 8000/10000 VA Input Circuit Breaker The input circuit breaker must be switched on for the UPS to operate. The input circuit brea

Seite 15 - MAINTENANCE, SERVICE

5 CONNECT THE EXTERNAL BATTERIES Battery Safety Read and adhere to the following warnings when installing or servicing the external batteries.

Seite 16 - TROUBLESHOOTING

6 THIRD PARTY BATTERY SOLUTION Batteries must be Sealed Lead-Acid type. Use 50 A, 250 VDC fuses with an Interrupt rating of ≥ 20,000 A. Ensure that

Seite 17

7 CONNECT EQUIPMENT AND POWER TO THE UPS 1. Connect equipment to the UPS. 2. Turn on all connected equipment. To use the UPS as a master ON/OF

Seite 18 - Limited Warranty

8 TERMINAL MODE TO CONFIGURE UPS PARAMETERS AND PROGRAM THE NUMBER OF BATTERY PACKS Terminal Mode is a menu driven interface that enables enhanced c