Protection
Sine-wave Output
provides assurance of compat-
ibility with all types of loads.
Lightning and Surge Protection
Integrated
Surge Suppression is superior to separate surge
suppressors.
Network-grade Line Conditioning provides full
time EMI/RFI filtering, thus preventing data errors
caused by line noise.
Emergency Power Off (EPO)
SURT XL can
be attached to central EPO system for shutdown in an
emergency situation.
Unattended Safe & Graceful Shutdown
prevents possible data corruption by providing
systematic, unattended operating system shutdown in
the event of an extended power outage.
Alarms and Indicators
provide operational
status information of the UPS instantaneously.
Availability
Zero Transfer Time
ensures no interruption of
mission-critical applications when UPS transfers
to/from the batteries.
Wide Input Voltage Range
160-280 VAC input
voltage range at full load allows less time on battery
while preserving battery capacity for blackout condi-
tions. Input voltage can go as low as 100 VAC, at half
load, without using the battery.
Continuous Voltage and Frequency Regulation
SURT XL
provides premium, regulated sine-
wave power for sensitive equipment. SURT XL
is also generator-set compatible.
Built-in Automatic & Manual Bypass
ensures
continuous supply of power to the critical loads in the
event of electronic failure, overload condition, or
scheduled maintenance.
Scalable Runtime
Unlimited number of matching
battery packs can be added to increase runtime to
desired levels.
Faster Recharge Time
ensures battery
power is available more quickly for subsequent
power disturbances.
Cold Start
allows the unit to be powered without
input power being available.
Intelligent Battery Management
utilizes micro-
processor to control battery charging and diagnostic
testing ensuring maximum battery life.
Hot-Swappable, User Replaceable Batteries
allow continuous operation of the load when batter-
ies are being replaced by the end user.
Economy
Input Power Factor Correction increases
safety and compliance with regional wiring/
electrical standards. Also reduces the utility power
and wiring costs.
Replace Battery
lights and alarm sounds when
the UPS battery is nearly dead and must be
replaced (typically within 30 days).
Battery Charge/Line Voltage
displays both
present battery charge as a percentage of battery
capacity and utility line voltage. Alarm sounds upon
low battery condition.
Off Button
turns off the UPS and the load and is
designed to prevent accidental shutdowns.
On/test button turns on the UPS and activates the
UPS self-test and utility line voltage displays.
Load Display
shows the power being drawn
by the load so you can avoid exceeding capacity
.
On-line LED
lights when the UPS is drawing
utility power and performing double conversion
to supply clean power.
On-Battery LED lights and alarm sounds when
the UPS is supplying battery power to the load.
Bypass LED
lights when unit is operating in
bypass mode.
Overload LED
lights and alarm sounds when
the load connected to the UPS exceeds capacity.
Fault LED
lights when unit is experiencing an
internal fault.
Display can be rotated 90° for correct orientation as unit is
shifted from tower to rack configuration.
Adaptability
Rack/Tower Convertible
gives SURT XL a
flexible form factor enabling integration into a wide
variety of end-user environments.
1:1 and 3:1 Combined in a Single Product
allows the same product to be wired to a single-
phase or a three-phase input. This feature is avail-
able in SURT XL 7500/10000 VA models only.
Multiple Output Voltages
230 VAC nominal out-
put voltage can be programmed for 220 or 240 VAC
operation.
Auto-sensing and Programmable
Frequency
automatically provides 50 or 60 Hz. The
end user can also set output frequency to desired
tolerance levels.
Flash Programmable Firmware makes the UPS
field-upgradeable.
Terminal Mode Programmability
is a
menu-driven interface that allows quick and easy
configuration of the UPS. Ideal for users not using
PowerChute
®
software or a management card.
Built-in SmartSlot
houses APC’s accessory cards,
which increase overall system manageability through
timely notification of hazardous conditions.
INFORMATIVE LED DISPLAY PROVIDES STATUS AT A GLANCE
A
B
C
D
E
F
G
H
I
J
A
B
C
D
E
F
G
H
I
J
APC accessory cards can be inserted into the built-in
SmartSlot to allow monitoring of power conditions.
The SURT XL 5000, 7500, and 10,000 units ship bun-
dled with the Web/SNMP Management Card
Redundancy
Automatic Transfer Switch Application
pro-
vides redundant power to single-corded equipment.
PowerChute
®
Network Shutdown Software
allows for simultaneous management of two UPSs.
Supports multiple servers as well as 2N configura-
tions. Servers with one primary and one redundant
power supply can be plugged into separate UPSs.
Features and Benefits
3000VA Automatic
Transfer Switch
User-friendly, hot-swappable battery replacement
For more information about APC products go to www.APCturkey.com