EDA 1200 System Overview
The EDA RSC96c is environmentally hardened
outdoor cabinet used for roll-out solutions close
to the End-user. It is ordered and delivered fully
equipped.
The cabinet solution scales from 12 to 96
subscribers and uses standard EDA Nodes. It
is equipped with an ESN212 switch and one to
eight EDN612 IP DSLAMs, enabling VDSL2,
ADSL2+, ADSL2 and ADSL transmission modes.
Alternatively, an ESN204g switch can be used with
one to four EDN612 IP DSLAMs.
To increase the capacity of fiber lines, a Coarse
Wave Division Multiplexer (CWDM) can be used
(ESN212 switch only).
The cabinet uses direct air cooling instead of a
traditional heat exchange Unit.
Each RSC96c provides MDF capacity for 1:2
overlay, that is, up to 600 pairs of High Band
MDF blocks for VDSL2, located in a separate
compartment accessible from the top of the
cabinet.
Flexible AC/DC powering solutions are available
for optional redundancy and up to 6 hours battery
backup.
The cabinet is designed for ground mounting on
a plinth and the dimensions (excluding the plinth)
are:
HxWxD: 1180x610x490 mm