Output Fields
Field Description
Interface Index
This specifies the interface index used for the
Aggregator type of interfaces. Valid Value is
aggr-0
IP Address
This specifies the IP address configured for the
interface.
Mask
This specifies the network mask configured for
the interface. If either of 'IP Address' or 'mask' is
non-null the other must also be non-null and vice
versa.
UseDhcp
This specifies whether a DHCP client is to be
triggered to obtain an IP address for this
interface from a DHCP server.
Mgmt VLAN Index
VLAN(C-Vlan) for management traffic on this
interface. Non-zero value of this field is valid
only if either 'ip' field is non-zero or 'usedhcp'
field is true. If no Management Vlanid is
specified (in the create operation) or it's value is
set to zero (either in create or modify operation)
then the system shall use the value of
'portvlanid' associated with the bridge port
created on this interface as the Management
Vlan Index. In case the management vlan (i.e.
'mgmtvlanid' or the associated 'portvlanid', if
'mgmtvlanid' is zero) doesn't exist on the system
then IP based management on this management
VLAN shall not happen on the interface till the
corresponding VLAN is created with the Net side
port as its member.
Mgmt S-VLAN Index
Applicable only in stacked vlan mode, this is S-
Vlan for management traffic on this interface.
Non-zero value of this field is valid only if either
'ip' field is nonzero or 'usedhcp' field is true. If no
management Svlanid is specified (in the create
operation) or it's value is set to zero (either in
create or modify operation) then the system shall
use the value of 'psvlanid' associated with the
bridge port created on this interface as the
management vlan id. In case the management
vlan (virtual vlan mapped to S-VLAN and C-
VLAN for the frame) doesn't exist (ie. Virtual vlan
mapped to 'mgmtsvlanid' or the associated '
psvlanid ', if 'mgmtsvlanid' is zero) on the system
then IP based management shall not happen on
the interface till the corresponding virtual-VLAN
is created with the Net side port as its member.
Tagged Mgmt PDU Prio
Priority to be set in Tagged Ethernet PDUs sent
on Management VLAN over this interface. This
field is valid only if either 'ip' field is non-zero or
'usedhcp' field is true. In Native Vlan mode this
priority shall be used for C-Vlan tag while in
stacked vlan mode it shall be used for S-Vlan
tag.
Oper Status
The actual/current state of the interface. It can
be either up or down.
Admin Status
The desired state of the interface. It may be
either Up or Down.
Cautions
If an aggregator interface is being created, all configurations of
aggregated links (layer2 ethernet interfaces), should be same.
8.4.3 LACP Aggr Commands
8.4.3.1 Get lacp aggr
Description: Use this command to get.
Seitenansicht 167