Seitenansicht 278
271
aturconfmaxnomatpu
s
<aturconfmaxnomatpus
-val>
This parameter specifies the maximum nominal
aggregate transmit power(MAXNOMATP) level
during initialization and showtime. Value depends
on CO MIB element settings and local capabilities
and is exchanged in the G.994.1 Phase. It is
available only for ADSL2/ADSL2plus. Value
ranges from 0 to 25.5 in steps of 0.1 dBm.(length
= 4 bytes)
Type: Modify -- Optional
Valid values: 0 - 255
atucconfpsdmaskds
<atucconfpsdmaskds-
val>
This configuration parameter defines that the
downstream PSD mask applicable at the U-C2
reference point. This MIB PSD mask may impose
PSD restrictions in addition to the Limit PSD mask
defined in the relevant Recommendation (e.g.,
G.992.5). (length = 4 bytes).
Type: Modify -- Optional
aturconfpsdmaskus
<aturconfpsdmaskus-
val>
This configuration parameter defines that the
upstream PSD mask applicable at the U C2
reference point. This MIB PSD mask may impose
PSD restrictions in addition to the Limit PSD mask
defined in the relevant Recommendation (e.g.,
G.992.5). It is available only for Annexes J and M
of ADSL2/ADSL2plus.(length = 4 bytes)
Type: Modify -- Optional
aturratemode fixed |
adaptAtStartup |
adaptAtRuntime
Defines what form of transmit rate adaptation is
configured on this modem. The default value
mentioned is an indicative value only.
Type: Modify -- Optional
aturconfmininp Inp0 |
InpPoint5 | Inp1 | Inp2 |
InpAuto | Inp4 | Inp8 |
Inp16
Parameter used to specify the minimum impulse
noise protection for the upstream bearer channel.
Supported for ADSL2/ADSL2plus ONLY
Type: Modify -- Optional
gsannexcoltocxswitc
h CxSwitch19DB |
CxSwitch20DB |
CxSwitch21DB |
CxSwitch22DB |
CxSwitch23DB |
CxSwitch24DB |
CxSwitch25DB |
CxSwitch26DB |
CxSwitch27DB |
CxSwitch28DB |
CxSwitch29DB |
CxSwitch30DB
Conexant parameter that is used to configure the
switching point between DBM-OL and XOL.(length
= 4 bytes)
Type: Modify -- Optional
atucconfgsannexcswi
tch Gspan19DB |
Gspan20DB |
Gspan21DB |
Gspan22DB |
Gspan23DB |
Gspan24DB |
Gspan25DB |
GspanPlus7DB |
GspanPlus8DB |
GspanPlus9DB |
GspanPlus10DB |
GspanPlus11DB |
GspanPlus12DB |
GspanPlus13DB |
GspanPlus14DB |
GspanPlus15DB
Conexant parameter that is used to configure the
switching point between Annex C and G.Span
(IFM) and between Annex C and G.Span
Plus.(length = 4 bytes)
Type: Modify -- Optional