270
mode. By selecting the receive start and end bin
numbers, the user can limit the bins for special
configurations.(length = 4 bytes)
Type: Modify -- Optional
gspsdmaskdsenable
PsdMaskDisable |
PsdMaskEnable |
PsdMaskEnableMod
Conexant parameter that is used to configure the
switching point between DBM-OL and XOL.(length
= 4 bytes)
Type: Modify -- Optional
gspsdmaskusenable
PsdMaskDisable |
PsdMaskEnable |
PsdMaskEnableMod
Conexant parameter used to enable the Mask on
Demand(MoD) feature in the upstream direction. It
is available only for ADSL2 Annex A ONLY.(length
= 4 bytes)
Type: Modify -- Optional
psdmaskdsfallbacken
able False | True
Conexant parameter used to enable Mask on
Demand (MoD) fallback mode. When enabled, the
system chooses MoD or the base ADSL2
depending upon the downstream rate. It is
avaiable only for ADSL2 Annex A.(length = 4
bytes)
Type: Modify -- Optional
Valid values: False, True
psdmaskusfallbacken
able False | True
Conexant parameter used to enable Mask on
Demand (MoD) fallback mode. When enabled, the
system chooses MoD or the base ADSL2
depending upon the upstream rate. It is avaiable
only for ADSL2 Annex A.(length = 4 bytes)
Type: Modify -- Optional
Valid values: False, True
atucconfmaxnompsd
ds
<atucconfmaxnompsdd
s-val>
This parameter specifies the maximum nominal
transmit PSD(MAXNOMPSD) level during
initialization and showtime. Value depends on CO
MIB element settings and near end transmitter
capabilities and is exchanged in the G.994.1
Phase. It is available only for ADSL2/ADSL2plus.
Value ranges from -60 to -40 in steps of 0.1
dBm/Hz.(length = 4 bytes)
Type: Modify -- Optional
Valid values: (-600) - (-400)
aturconfmaxnompsdu
s
<aturconfmaxnompsdu
s-val>
This parameter specifies the maximum nominal
transmit PSD(MAXNOMPSD) level during
initialization and showtime. Value depends on CO
MIB element settings and near end transmitter
capabilities and is exchanged in the G.994.1
Phase. It is available only for ADSL2/ADSL2plus.
Value ranges from -60 to -38 in steps of 0.1
dBm/Hz.(length = 4 bytes)
Type: Modify -- Optional
Valid values: (-600) - (-380)
atucconfmaxnomatpd
s
<atucconfmaxnomatpd
s-val>
This parameter specifies the maximum nominal
aggregate transmit power(MAXNOMATP) level
during initialization and showtime. Value depends
on CO MIB element settings and local capabilities
and is exchanged in the G.994.1 Phase. It is
available only for ADSL2/ADSL2plus. Value
ranges from 0 to 25.5 in steps of 0.1 dBm.(length
= 4 bytes)
Type: Modify -- Optional
Valid values: 0 - 255