485
consideration for modifytos action and other bits
are ignored. In the mask if a bit location contains
1, then the corresponding bit in the TOS field is
overwritten with the corresponding bit in action
value. In the mask if a bit location contains 0, then
the corresponding bit in the TOS field remains
unchanged.
Application
Description
Description of the application that receives
packets matching this RL. This field is mandatory
if Action is 'sendtocontrol' or 'copytocontrol'.The
description string should not begin with
underscore '_' as it is reserved for special usage
e.g. _PPPOE_CONTROL.
8.21.6 Rl instance info Commands
8.21.6.1 Get rl instance info
Description: Use this command to get.
Command Syntax: get rl instance info [instanceid <instanceid-val>]
8.21.6.2 Create rl instance info
Description: Use this command to create.
Command Syntax: create rl instance info instanceid <instanceid-
val> profileid <profileid-val> actionprofileid <actionprofileid-val>
8.21.6.3 Delete rl instance info
Description: Use this command to delete.
Command Syntax: delete rl instance info instanceid <instanceid-
val>
Parameters
Name Description
instanceid
<instanceid-val>
Rate limiter instance identifier, which uniquely
identifies a rate limiter instance.
Type: Create -- Mandatory
Delete -- Mandatory
Get -- Optional
Valid values: 1 - 250
profileid <profileid-
val>
This field identifies the rate limiter instance's
configuration profile. The rate limiter's algorithm
and associated parameters are based on the
configuration profile.
Type: Create -- Mandatory
Valid values: 1 - 16
actionprofileid
<actionprofileid-val>
This field identifies the rate limiter instance's
action profile. The rate limiter's actions on a
packet depending on the result are based on the
action profile.
Type: Create -- Mandatory
Valid values: 1 - 32
Example
$ create rl instance info instanceid 3 profileid 2 actionprofileid 1
Output
Verbose Mode On